Hot Aqua PRAEFURNIUM duplex tympanum
Parameter:
Aqua calida SZL supportantes Impetus PRAEFURNIUM
Parameter List principalis Technology
model
item |
SZL2.8-1.0 / CXV / LXX-XII
SZL2.8-1.25 / CXXX / LXX-XII |
SZL4.2-1.0 / CXV / LXX-XII
SZL4.2-1.25 / CXXX / LXX-XII |
SZL5.6-1.0 / CXV / LXX-XII
SZL5.6-1.25 / CXXX / LXX-XII |
|||
rated Quantitate | 2,8T / h | 4,2 T / h | 5,6 T / h | |||
Working Pressure rated Mpa | 1.0 / 1.25 | 1.0 / 1.25 | 1.0 / 1.25 | |||
Vapor rated area. ℃ | 115/130 | 115/130 | 115/130 | |||
Pascere aqua area. ℃ | 70 | 70 | 70 | |||
Cibus consummatio kg / B | ~ DLXXX | ~ CM | ~ MCXXX | |||
Efficens scelerisque% | 78 | 80 | 80 | |||
heating Superficiem | Corpus boiler m² | 80.5 | 142 | 178 | ||
Economizer m² | 38,5 | 87.2 | 122,08 | |||
Vestiesque illud area m² | 4.84 | 7.78 | 10,42 | |||
Design Fule | bituminosa Coal | |||||
Max. Pondus onerariam | XXX T | ~ 25T | ~ 26T | |||
Max. Ratio lacus m | 6.9x2.5x3.5 | Up6.09x3.04x3.6
D: 7.3x2.86x1.72 |
6.9x3.33x3.55 | |||
Auxiliaris et Specification Model boiler Equipment | ||||||
aeris CERAULA | model | 4 A T4-72-11
CCCXV ° ius |
5A T4-72-11
CCXXV ° ius |
GC8-1
CCXXV ° ius |
||
potestate motoria | Kw N = 5.5 | XI N = Kw | XI N = Kw | |||
Ventilabrum conscripsit | model | Y9-26 9D
Ius 0 |
Y8-39 9D
Ius 0 |
GY8-1
Ius 0 |
||
potestate motoria | XXII N = Kw | XXX N = Kw | XXXVII N = Kw | |||
calces Box | model | 5P GL, | GL, 10p | GL, 10p | ||
potestate motoria | Kw N = 0,55 | N = 1.1Kw | Kw N = 1.1 | |||
Pascere aqua pump | model | 1 ½ GC5x7 | 5x5 2GC, | 5x4 2GC, | ||
potestate motoria | Kw N = 7.5 | XI N = Kw | XI N = Kw | |||
pulvis Aufero | D-IV | D-VI | VIII-XII |
model
item |
SZL7-1.0 / CXV / LXX-XII
SZL7-1.25 / CXXX / LXX-XII |
SZL10.5-1.0 / CXV / LXX-XII
SZL10.5-1.25 / CXXX / LXX-XII |
SZL14-1.0 / CXV / LXX-XII
SZL14-1.25 / CXXX / LXX-XII |
SZL17.5-1.0 / CXV / LXX-XII
SZL17.5-1.25 / CXXX / LXX-XII |
|
rated Quantitate | 7T / h | 10,5 T / h | 14 T / h | 17,5T / h | |
Working Pressure rated Mpa | 1.0 / 1.25 | 1.0 / 1.25 | 1.0 / 1.25 | 1.0 / 1.25 | |
Vapor rated area. ℃ | 115/130 | 115/130 | 115/130 | 115/130 | |
Pascere aqua area. ℃ | 70 | 70 | 70 | 70 | |
Cibus consummatio kg / B | ~ MCD | MCM ~ | ~ MMDCC | ~ MMMDCL | |
Efficens scelerisque% | 82 | 82 | 82 | 82 | |
heating Superficiem
m² |
radialis tube | 39.43 | 37.21 | 58.4 | 58.4 / 68.4 |
ripae convection | 213.4 | 284,68 | 307,4 | 307.4 / 384.8 | |
Economizer m² | 122,08 | 130.8 | 413 | 413/521 | |
Vestiesque illud area m² | 11.99 | 17.81 | 22.56 | 24.52 | |
Design Fule | Bituminosa Coal (Maximum locum calor valorem, 19228Ki / kg) | ||||
Max. Pondus onerariam | T XL ~ | ~ 43T | ~ 30T | ~ 30T | |
Max. onerariam ratio | 7.9x3.2x3.5 | 10x3.2x3.5 | 11x3.2x3.5 | 12x3.2x3.54 |